CyberPower HSTP3T20KEBCWOB uninterruptible power supply (UPS) Double-conversion (Online) 20000 VA 18000 W
EAN:
4712856278002
Part number:
HSTP3T20KEBCWOB
Payment methods
![](https://gfx2.senetic.com/gfx/footer-icons/visa.png)
![](https://gfx2.senetic.com/gfx/footer-icons/mastercard.png)
Delivery methods
![](https://gfx2.senetic.com/gfx/footer-icons/ups.png)
![](https://gfx2.senetic.com/gfx/delivery-product-icon-dpd.png)
![](https://gfx2.senetic.com/gfx/footer-icons/dhl.jpg)
> Three Phase Tower UPS
> Online (Double Conversion) UPS Topology
> ECO Mode
> UPS Parallel Expansion
> Dual Inputs
> Generator Compatible
> Pure Sine Wave Output
> Overload Protection
> Maintenance Bypass Switch
> LCD Status Display
> Emergency Power Off (EPO) Port
> PowerPanel® Management Software
![](https://gfx2.senetic.com/gfx/product-page/solutions.png)
We find the optimal solution for your business. Our sales and presales specialists select products and services for our customers every day.
![](https://gfx2.senetic.com/gfx/product-page/delivery.png)
We guarantee on-time delivery of your equipment wherever you are. We work with global partners to ensure our logistics are optimised.
![](https://gfx2.senetic.com/gfx/product-page/support.png)
We offer support in implementing solutions in your business. Our qualified engineers help you manage your infrastructure effectively.
![](https://gfx2.senetic.com/gfx/product-page/customer.png)
Our RMA experts deal with complaints and equipment replacements quickly and efficiently, so that your business can run smoothly.
Description
CyberPower HSTP3T20KEBCWOB. UPS topology: Double-conversion (Online), Output power capacity: 20 kVA, Output power: 18000 W. Serial interface type: RS-485. Typical backup time at full load: 7 min, Typical backup time at half load: 18 min. Form factor: Tower, Product color: Black, Housing material: Metal. Certification: CE , IEC62040-1 , IEC62040-2
Specifications
Features
UPS topology
![The two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances. UPS topology](https://gfx.senetic.com/gfx/help_new.png)
Double-conversion (Online)
Output power capacity
![The maximum power that the device can produce. Output power capacity](https://gfx.senetic.com/gfx/help_new.png)
20 kVA
Output power
![The power that the device can produce. Output power](https://gfx.senetic.com/gfx/help_new.png)
18000 W
Waveform
Pure sine
Input operation voltage (min)
![The minumum voltage needed by the device during operation. Input operation voltage (min)](https://gfx.senetic.com/gfx/help_new.png)
220 V
Input operation voltage (max)
![The maximum input voltage supported by the device. Input operation voltage (max)](https://gfx.senetic.com/gfx/help_new.png)
415 V
Input frequency
![The frequency (Hz) which is required to power the product. Input frequency](https://gfx.senetic.com/gfx/help_new.png)
50/60 Hz
Output operation voltage (min)
![The minumum voltage produced by the device during operation. Output operation voltage (min)](https://gfx.senetic.com/gfx/help_new.png)
220 V
Output operation voltage (max)
![The maximum output voltage produced by the device. Output operation voltage (max)](https://gfx.senetic.com/gfx/help_new.png)
415 V
Efficiency
95%
Efficiency (ECO mode)
98%
Efficiency (Battery mode)
95%
Power factor
0.9
Input power factor
0.99
Power Factor Correction (PFC) type
Active
Crest factor
3:1
ECO mode
Yes
Total Harmonic Distortion (THD) (linear load)
1%
Total Harmonic Distortion (THD) (non-linear load)
5.5%
EMI/RFI noise filtering
Yes
Noise level
![The amplitude level of the undesired background noise, usually measured in decibels (db). Noise level](https://gfx.senetic.com/gfx/help_new.png)
58 dB
Power protection features
![Features that protect the device against power problems e.g. overload. Power protection features](https://gfx.senetic.com/gfx/help_new.png)
Overload
Audible alarm(s)
![Alarms that make a sound when they are activated (set off). Audible alarm(s)](https://gfx.senetic.com/gfx/help_new.png)
Yes
Audible alarm modes
Fault, Low battery alarm, Overload alarm
Maximum number of paralleling UPSs
4
Ports & interfaces
Serial interface
Yes
Serial interface type
RS-485
RS-232 ports
![The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports. RS-232 ports](https://gfx.senetic.com/gfx/help_new.png)
1
Emergency Power Off (EPO) connector
Yes
Battery
Typical backup time at full load
![The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity). Typical backup time at full load](https://gfx.senetic.com/gfx/help_new.png)
7 min
Typical backup time at half load
![The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity). Typical backup time at half load](https://gfx.senetic.com/gfx/help_new.png)
18 min
Design
Housing material
![What the casing of the product is made of. Housing material](https://gfx.senetic.com/gfx/help_new.png)
Metal
Form factor
![The shape or design of the product. Form factor](https://gfx.senetic.com/gfx/help_new.png)
Tower
Product colour
![The colour e.g. red, blue, green, black, white. Product colour](https://gfx.senetic.com/gfx/help_new.png)
Black
Display type
![Type of display (screen) e.g. LCD. Display type](https://gfx.senetic.com/gfx/help_new.png)
LCD
LED indicators
Yes
International Protection (IP) code
![The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as International Protection (IP) code](https://gfx.senetic.com/gfx/help_new.png)
IP20
Operational conditions
Operating temperature (T-T)
![The minimum and maximum temperatures at which the product can be safely operated. Operating temperature (T-T)](https://gfx.senetic.com/gfx/help_new.png)
0 - 40 °C
Storage temperature (T-T)
![The minimum and maximum temperatures at which the product can be safely stored. Storage temperature (T-T)](https://gfx.senetic.com/gfx/help_new.png)
-40 - 70 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Certificates
Certification
CE , IEC62040-1 , IEC62040-2
Weight & dimensions
Width
![The measurement or extent of something from side to side. Width](https://gfx.senetic.com/gfx/help_new.png)
350 mm
Depth
![The distance from the front to the back of something. Depth](https://gfx.senetic.com/gfx/help_new.png)
738 mm
Height
![The measurement of the product from head to foot or from base to top. Height](https://gfx.senetic.com/gfx/help_new.png)
1335 mm
Weight
![Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies. Weight](https://gfx.senetic.com/gfx/help_new.png)
89 kg
Packaging data
Package width
![The distance from one side of the packaging to the other. Package width](https://gfx.senetic.com/gfx/help_new.png)
490 mm
Package depth
![The distance from the front to the back of the packaging. Package depth](https://gfx.senetic.com/gfx/help_new.png)
880 mm
Package height
![The distance from the top to the bottom of the packaging. Package height](https://gfx.senetic.com/gfx/help_new.png)
1530 mm
Package volume
106000 cm³
Other features
Bypass
Automatic, Manual
SKU:
1060443
Empty field
Incorrect format
Incorrect format